  • PERFORMANCE
    Pulses per revolution 1,024
    Measuring step 90°, electric/pulses per revolution
    Measuring step deviation at non binary number of lines 0.07°
    Measuring step deviation at binary number of lines 0.035°
    Error limits binary pulses 0.09°
    Error limits non-binary pulses 0.13°
    Initialization time 40 ms
  • ELECTRICAL DATA
    Electrical interface 10 V … 30 V, HTL/Push pull
    Connection type Cable, 8-wire, universal, 0.5 m 1)
    Operating current ≤ 40 mA (without load)
    Output frequency ≤ 200 kHz
    Reference signal, number 1
    Reference signal, position 90°, electric, logically gated with A and B
    MTTFd: mean time to dangerous failure 600 years (EN ISO 13849-1) 2)
    • 1) The universal cable outlet is positioned in such a way, that it is possible to lay the cable in a radial or axial direction without kinking it.
    • 2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
  • MECHANICAL DATA
    Mechanical interface Solid shaft, face mount flange
    Shaft diameter 13 mm
    Weight 0.18 kg
    Start up torque 0.6 Ncm (+20 °C)
    Operating torque 0.4 Ncm (+20 °C)
    Operating speed 6,000 U/min
    Moment of inertia of the rotor 6 gcm²
    Bearing lifetime 2 x 10^9 revolutions
  • AMBIENT DATA
    EMC EN 61000-6-2

    EN 61000-6-3

    Enclosure rating IEC 60529
    Operating temperature range 0 °C … +60 °C
    Storage temperature range –40 °C … +70 °C, without package
    Resistance to shocks 50 g, 7 ms (EN 60068-2-27)
    Resistance to vibration 20 g, 10 Hz … 2,000 Hz (EN 60068-2-6)
    Air humidity 90 % 1)
    • 1) Condensation of the optical scanning not permitted.