range of product |
Zelio Logic |
|
---|---|---|
product or component type |
Modular smart relay |
local display |
With |
|
---|---|---|
number or control scheme lines |
0…500 with FBD programming 0…240 with ladder programming |
|
cycle time |
6…90 ms |
|
backup time |
10 yearsat 77 °F (25 °C) |
|
clock drift |
6 s/monthat 77 °F (25 °C) 12 min/yearat 32…131 °F (0…55 °C) |
|
checks |
Program memory on each power up |
|
[Us] rated supply voltage |
100…240 V |
|
supply voltage limits |
85…264 V |
|
supply frequency |
50/60 Hz |
|
supply current |
100 mAat 100 V (without extension) 50 mAat 240 V (without extension) 60 mAat 240 V (with extensions) 80 mAat 100 V (with extensions) |
|
power consumption in VA |
12 VA without extension 17 VA with extensions |
|
isolation voltage |
1780 V |
|
protection type |
Against inversion of terminals (control instructions not executed) |
|
discrete input number |
16 |
|
discrete input voltage |
100…240 V AC |
|
discrete input current |
0.6 mA |
|
discrete input frequency |
47…53 Hz 57…63 Hz |
|
voltage state 1 guaranteed |
>= 79 Vfor discrete input |
|
voltage state 0 guaranteed |
<= 40 Vfor discrete input |
|
current state 1 guaranteed |
>= 0.17 mA for discrete input |
|
current state 0 guaranteed |
<= 0.5 mA for discrete input |
|
input impedance |
350 kOhm (discrete input) |
|
number of outputs |
10 relay output(s) |
|
output voltage limits |
24…250 V AC 5…30 V DC (relay output) |
|
contacts type and composition |
NO relay output |
|
output thermal current |
5 A for 2 outputs (relay output) 8 A for 8 outputs (relay output) |
|
electrical durability |
500000 cycles AC-12at 230 V, 1.5 Afor relay output conforming to EN/IEC 60947-5-1 500000 cycles AC-15at 230 V, 0.9 Afor relay output conforming to EN/IEC 60947-5-1 500000 cycles DC-12at 24 V, 1.5 Afor relay output conforming to EN/IEC 60947-5-1 500000 cycles DC-13at 24 V, 0.6 Afor relay output conforming to EN/IEC 60947-5-1 |
|
switching capacity in mA |
>= 10 mAat 12 V (relay output) |
|
operating rate in Hz |
0.1 Hz (at Ie)for relay output 10 Hz (no load)for relay output |
|
mechanical durability |
10000000 cycles (relay output) |
|
[Uimp] rated impulse withstand voltage |
4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 |
|
clock |
With |
|
response time |
10 ms (from state 0 to state 1) relay output 5 ms (from state 1 to state 0) relay output 50 ms with ladder programming (from state 0 to state 1) discrete input 50 ms with ladder programming (from state 1 to state 0) discrete input 50…255 ms with FBD programming (from state 0 to state 1) discrete input 50…255 ms with FBD programming (from state 1 to state 0) discrete input |
|
connections – terminals |
Screw terminals, clamping capacity: 1 x 0.2…1 x 2.5 mm² AWG 25…AWG 14 semi-solid Screw terminals, clamping capacity: 1 x 0.2…1 x 2.5 mm² AWG 25…AWG 14 solid Screw terminals, clamping capacity: 1 x 0.25…1 x 2.5 mm² AWG 24…AWG 14 flexible with cable end Screw terminals, clamping capacity: 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16 solid Screw terminals, clamping capacity: 2 x 0.25…2 x 0.75 mm² AWG 24…AWG 18 flexible with cable end |
|
tightening torque |
4.42 lbf.in (0.5 N.m) |
|
overvoltage category |
III conforming to EN/IEC 60664-1 |
|
product weight |
0.88 lb(US) (0.4 kg) |
immunity to microbreaks |
<= 10 ms |
|
---|---|---|
product certifications |
CSA C-Tick GL GOST UL |
|
standards |
EN/IEC 60068-2-27 Ea EN/IEC 60068-2-6 Fc EN/IEC 61000-4-11 EN/IEC 61000-4-12 EN/IEC 61000-4-2 level 3 EN/IEC 61000-4-3 EN/IEC 61000-4-4 level 3 EN/IEC 61000-4-5 EN/IEC 61000-4-6 level 3 |
|
IP degree of protection |
IP20 (terminal block) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529 |
|
environmental characteristic |
EMC directive conforming to EN/IEC 61000-6-2 EMC directive conforming to EN/IEC 61000-6-3 EMC directive conforming to EN/IEC 61000-6-4 EMC directive conforming to EN/IEC 61131-2 zone B Low voltage directive conforming to EN/IEC 61131-2 |
|
disturbance radiated/conducted |
Class B conforming to EN 55022-11 group 1 |
|
pollution degree |
2 conforming to EN/IEC 61131-2 |
|
ambient air temperature for operation |
-4…104 °F (-20…40 °C) in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2 -4…131 °F (-20…55 °C) conforming to IEC 60068-2-1 and IEC 60068-2-2 |
|
ambient air temperature for storage |
-40…158 °F (-40…70 °C) |
|
operating altitude |
6561.68 ft (2000 m) |
|
altitude transport |
<= 10000 ft (3048 m) |
|
relative humidity |
95 % without condensation or dripping water |
Category |
22378 – SR2,3 ZELIO 2 RELAYS |
|
---|---|---|
Discount Schedule |
I |
|
GTIN |
00785901571896 |
|
Nbr. of units in pkg. |
1 |
|
Package weight(Lbs) |
0.84999999999999998 |
|
Returnability |
Y |
|
Country of origin |
FR |
California proposition 65 |
WARNING: This product can expose you to chemicals including: |
|
---|---|---|
– – – – – – – Substance 1 |
Lead and lead compounds which is known to the State of California to cause cancer and birth defects or other reproductive harm. |
|
– – – – – – – More information |
For more information go to www.p65warnings.ca.gov |